Order quantity and mix
Order quantities are confirmed with sales according to the selected specifications and project requirements. Styles, colours, thicknesses and lengths can be mixed. List the area required for each option as well as the total.
For prefab and modular home manufacturers
Source exterior metal siding for repeatable building production. Compare the finish, review samples and prepare a mixed bulk order; share wall details when a technical check is needed.

Panel selection
Use the metal siding facade preview tool for illustrative visual comparisons before requesting samples.
Compare appearance families, then open the category and individual panel pages for real model images. Confirm colour, relief and formed profile with physical samples before selecting an order mix.
Solid colours & texturesReview colour or surface relief
Wood grainReview the printed pattern
Fluted profilesReview the formed face

Bulk panel supply
Tegravo manufactures metal siding panels for project orders. Start with the finishes and quantities you need for each building type; sales can review the proposed mix and shipment.
Order quantities are confirmed with sales according to the selected specifications and project requirements. Styles, colours, thicknesses and lengths can be mixed. List the area required for each option as well as the total.
All current models support standard 16 mm and 20 mm thicknesses. Ask sales about 30 mm or other thicknesses. Regular lengths, eight-panel packs and board-weight references are maintained in the series dimensions guide.
Sample pieces are about 350 mm long and free; the customer covers courier costs. Production timing, mixed-model scheduling and container capacity are confirmed for the actual order. Review ordering guidance.


Technical fit
Share the load-bearing frame or subframe, intended fixing zones, wall section and panel edge requirements. A fastening layout and complete wall performance need project-specific design and testing.
If your factory bonds or presses siding to another wall panel, also share the substrate, contact surfaces, foam or adhesive system, pressure, temperature, duration and proposed mechanical fixing. We recommend evaluating screws into a designed load-bearing member alongside bonding.
The PU core compressive-strength reference is not an allowable pressing pressure for a complete wall panel.
Technical documents
State the destination market, required standard and tested assembly. A PU core, a single panel and a complete wall system have different test results.
Tell us the required local standard, classification and wall configuration. The current “B grade” reference cannot be assumed to meet a different classification.
Ask which model, thickness and test object each available document describes. A core result does not establish the performance of a bonded wall assembly.
Review supports, fasteners, penetrations and joints against your wall design. For factory bonding, use samples to check the proposed process and finished assembly.
See the series technical data reference and fire-classification enquiry item
Application details
The manufacturing route is a project condition for selecting the panel and reviewing its joints. Share the relevant details; your team controls the building and transport design.
Mark the wall support, openings and module joints that need review after transport.
Show wall-to-wall joints and any finishing work planned after assembly.
Provide substrate, bonding conditions and the proposed mechanical fixing for sample review.
Provide the support, openings, corners and exposed ends at the installation location.
Terminology in enquiries: buyers may ask for metal siding, insulated metal panels (IMP) or sandwich panels. Tegravo’s documented construction has one metal face, a PU foam core and a foil/fibre backing; it should not be treated as a two-metal-face panel without matching the requested specification.
Bulk enquiry
Start with the purchase information you know. Add drawings and technical requirements where applicable; unknown values can be discussed later.
Open the enquiry pageCommon questions
The substrate, press process, bond and complete panel need review and sample testing. A core-only value is not a whole-panel limit.
We recommend evaluating mechanical fixing into a designed load-bearing support alongside bonding. The project designer must determine and test the fixing detail.
Not on that description alone. Share the required standard, classification and wall configuration so the relevant documents can be checked.