Skip to content
Shandong Tegravo Building Materials Technology Co., Ltd.

For prefab and modular home manufacturers

Metal siding for prefab and modular home manufacturers

Source exterior metal siding for repeatable building production. Compare the finish, review samples and prepare a mixed bulk order; share wall details when a technical check is needed.

Modular building units with finished exterior walls inside a workshop
Workshop scene showing modular building units; no specific panel model is identified.

Shortlist finishes for your building range

Use the metal siding facade preview tool for illustrative visual comparisons before requesting samples.

Compare appearance families, then open the category and individual panel pages for real model images. Confirm colour, relief and formed profile with physical samples before selecting an order mix.

Representative solid-colour and textured metal siding finishesSolid colours & texturesReview colour or surface relief Representative wood-grain metal siding finishesWood grainReview the printed pattern Representative fluted metal siding profilesFluted profilesReview the formed face
Dark horizontal exterior siding on a gable-roof building with pale eaves and window trim
Exterior appearance referenceDark horizontal siding with pale trim. Panel model and building method unconfirmed.

Plan a repeatable panel order

Tegravo manufactures metal siding panels for project orders. Start with the finishes and quantities you need for each building type; sales can review the proposed mix and shipment.

Order quantity and mix

Order quantities are confirmed with sales according to the selected specifications and project requirements. Styles, colours, thicknesses and lengths can be mixed. List the area required for each option as well as the total.

Thickness and packing

All current models support standard 16 mm and 20 mm thicknesses. Ask sales about 30 mm or other thicknesses. Regular lengths, eight-panel packs and board-weight references are maintained in the series dimensions guide.

Samples and scheduling

Sample pieces are about 350 mm long and free; the customer covers courier costs. Production timing, mixed-model scheduling and container capacity are confirmed for the actual order. Review ordering guidance.

Rows of different metal siding finish samples displayed in a sample room
Compare finishesSample-room display for appearance review; this is not a photograph of a shipped sample.
Long packed cartons stacked inside a warehouse
Review packed goodsLong cartons stacked indoors; the image does not identify a particular order or carton contents.

Prepare a bulk enquiry

Check the panel against your wall

Share the load-bearing frame or subframe, intended fixing zones, wall section and panel edge requirements. A fastening layout and complete wall performance need project-specific design and testing.

If your factory bonds or presses siding to another wall panel, also share the substrate, contact surfaces, foam or adhesive system, pressure, temperature, duration and proposed mechanical fixing. We recommend evaluating screws into a designed load-bearing member alongside bonding.

The PU core compressive-strength reference is not an allowable pressing pressure for a complete wall panel.

Request evidence for your requirement

State the destination market, required standard and tested assembly. A PU core, a single panel and a complete wall system have different test results.

Fire classification

Tell us the required local standard, classification and wall configuration. The current “B grade” reference cannot be assumed to meet a different classification.

Panel and core data

Ask which model, thickness and test object each available document describes. A core result does not establish the performance of a bonded wall assembly.

Connection and weathering

Review supports, fasteners, penetrations and joints against your wall design. For factory bonding, use samples to check the proposed process and finished assembly.

Tell us when the siding is fitted

The manufacturing route is a project condition for selecting the panel and reviewing its joints. Share the relevant details; your team controls the building and transport design.

Factory-fitted modules

Mark the wall support, openings and module joints that need review after transport.

Prefabricated wall sections

Show wall-to-wall joints and any finishing work planned after assembly.

Factory-bonded assemblies

Provide substrate, bonding conditions and the proposed mechanical fixing for sample review.

Site-fitted panels

Provide the support, openings, corners and exposed ends at the installation location.

Terminology in enquiries: buyers may ask for metal siding, insulated metal panels (IMP) or sandwich panels. Tegravo’s documented construction has one metal face, a PU foam core and a foil/fibre backing; it should not be treated as a two-metal-face panel without matching the requested specification.

Prepare your panel order details

Start with the purchase information you know. Add drawings and technical requirements where applicable; unknown values can be discussed later.

Open the enquiry page

Start with the order

  • Preferred panel category, models or finish shortlist
  • Area for each option and total order area in m²
  • Required thickness and preferred panel lengths
  • Destination country and port
  • Initial order and anticipated repeat requirements, if known

Add technical details if available

  • Wall section, substrate and load-bearing members
  • Fixing method, module joints and openings
  • Bond or press settings, only if applicable
  • Required fire standard and classification
  • Elevations, wall drawings or site photographs

Before you specify the panel

Can the siding be factory bonded to my wall panel?

The substrate, press process, bond and complete panel need review and sample testing. A core-only value is not a whole-panel limit.

Should a bonded panel also use screws?

We recommend evaluating mechanical fixing into a designed load-bearing support alongside bonding. The project designer must determine and test the fixing detail.

Does “B grade” meet my local fire requirement?

Not on that description alone. Share the required standard, classification and wall configuration so the relevant documents can be checked.