In this guide
Metal siding panels connect through formed edge interlocks. During a typical horizontal installation, each panel is engaged and mechanically fixed to a suitable supporting structure before the next panel is fitted. The interlock alone does not replace wall fixing.
There are three details to distinguish: panel-to-panel engagement along the long edges, panel-to-wall mechanical fixing, and the treatment of corners, ends and openings.
Key Takeaways
- Panels engage one by one along formed matching edges and are mechanically secured to a suitable supporting substrate.
- Estimate coverage using 383 mm effective width, not 430 mm overall width.
- Confirm screw type, length, spacing and supporting structure for the selected profile and project.
- Aluminium trims suit both standard thicknesses; do not assume different thicknesses can interlock.
- Confirm the SKU, thickness, direction, openings and accessory requirements before ordering.
Understanding the Panel Edge Profile
A finished panel combines a decorated exterior metal face, PU foam core and inner backing. Its formed metal edges provide the connection geometry. The male edge is the projecting formed edge; the female edge is the matching receiving edge. The fixing edge is the region used by the typical concealed fixing arrangement.

Decorative formed grooves are different from the actual joint between adjacent panels. A wood, brick or stone motif does not establish the joint shape. Read the edges and section from the actual product or a verified drawing. See insulated metal siding panels for the three-layer construction.
How the Interlocking Connection Works
Before engagement, check that both formed edges are clean and undamaged. Bring the matching male and female edges together along the panel length. Full-length engagement matters: partial seating can leave uneven joints or open edges. In a typical concealed fixing arrangement, the following panel covers part of the preceding panel's fixing position.
SSG-BT-WG001 illustrates the general principle in the following photographs. The same SKU is shown before and after engagement, not the precise section of every SKU.


Three Types of Metal Siding Panel Connections
Long-edge interlock
Matching male and female edges connect along the length of adjacent panels.
End-to-end joint
Use an appropriate H-joint or other specified connection where a run exceeds one panel length.
Corners and openings
Separate corner, opening and termination trims complete these details.
Standard panel lengths are 2,900, 3,800 and 5,800 mm; plan end joints against the wall layout and the length selected.
An ordinary H-joint trim should not be assumed to serve as a structural movement joint or modular building movement joint. Movement details between independent modules are designed separately.
How Metal Siding Panels Are Fixed to the Wall
The edge joint locates adjacent panels. Each panel must also be mechanically secured to a suitable supporting structure, such as approved steel framing or secondary supports. In a typical concealed fixing layout the next panel covers part of the preceding fixing region.

Fixing points, screw type, length, spacing and support capacity are confirmed against the actual profile and project design. Plasterboard or another decorative, non-load-bearing facing alone must not be assumed to be a fixing substrate; confirm the load-bearing members or designed secondary supports. Review the pre-installation checklist.
Typical Panel Connection Sequence
The following horizontal installation sequence describes the purpose of each stage. Actual orientation, fixing locations, water management and details follow the selected profile and approved project drawings.

Installation demonstration reference. Check support and layout
Confirm supporting members, alignment and opening positions.

Installation demonstration reference. Set the starter trim
Establish the starting line and secure the starter to the designed support.
Seat the first panel
Engage the first panel with the starter detail along its length.
Secure the panel
Mechanically fix the designated fixing edge into the verified support.

Installation demonstration reference. Engage the next panel
Seat the entire matching joint and then secure the next panel.

Installation demonstration reference. Complete the details
Finish corners, ends and openings at the stages required by the approved detail.
Starter trim is fitted before the first panel. Corner, door, window and end trims may need to be positioned before, during or after panel installation, depending on the selected detail.
Overall Width vs. Effective Coverage Width
For standard Tegravo panels, overall width is 430 mm and effective installed coverage width is 383 mm. The formed connection region is included in the physical width; do not infer insertion depth or overlap from these two dimensions.
For ten complete horizontal courses, theoretical cumulative coverage height is 10 × 383 mm = 3,830 mm. Check wall boundaries, starter and top cuts separately; this calculation is not a final layout take-off. See how to calculate exterior wall cladding area.
Connecting 16 mm and 20 mm Panels
All current SKUs are available in both standard thicknesses.
| Comparison item | 16 mm | 20 mm |
|---|---|---|
| Overall width | 430 mm | 430 mm |
| Effective coverage width | 383 mm | 383 mm |
| Fastener length | Confirm with substrate and project | Longer screws; exact length confirmed with project |
| Aluminium trim compatibility | Suitable | Suitable |
| Colour-matched accessories | Custom | Custom |
| Joint compatibility | Confirm selected SKU | Confirm before mixing thicknesses |
The required screw length difference is not automatically equal to the thickness difference. Matching coverage widths do not establish identical joints or direct interoperability. Confirm any face-level difference, transition and termination arrangement. See the thickness comparison guide.
Trims and Accessories for Panel Connections
| Accessory | Typical purpose |
|---|---|
| Starter trim | Locates the first panel at the starting line |
| Internal corner trim | Finishes an internal corner |
| External corner trim | Finishes an external corner |
| H-joint trim | Treats an end-to-end joint where provided |
| Window and door trim | Treats openings and reveals |
| End trim | Finishes panel ends or wall termination |
| Fasteners | Secure panels to supporting structure |

Aluminium accessories suit both 16 mm and 20 mm panels; matching decorative accessories are custom-made. Confirm the individual accessory profile, dimensions and supply configuration with sales.
See the metal siding trims and accessories guide for accessory selection and preliminary quantity planning.
Common Connection Mistakes
| Mistake | Why it matters | What to check |
|---|---|---|
| Interlock as the only fixing | Does not replace wall fixing | Confirm mechanical fixing to suitable supports |
| Partial edge engagement | Can leave open or uneven joints | Check full-length engagement |
| Uneven or unsuitable support | Affects alignment and fixing | Verify alignment and capacity |
| Unconfirmed screw length | May not provide adequate anchorage | Confirm screw type and effective anchorage |
| Using overall width for coverage | Overstates coverage | Calculate from 383 mm effective width |
| Mixing thicknesses | Joint shape and face level may differ | Confirm compatibility and transitions |
| Ignoring ends, corners and openings | Leaves details unplanned | List separate details and accessories |
| Leaving metal cuttings | Swarf may stain the finish | Clear cuttings and protect the coating |
What to Confirm Before Ordering
Send the following information with your enquiry so the team can review the selected panel, proposed fixing and accessories.
- Selected panel SKU
- Panel thickness
- Panel length
- Installation direction
- Wall or framing type
- Supporting structure drawings
- Panel connection requirements
- Internal and external corners
- Window and door openings
- End joints and termination details
- Required trims and accessories
- Project location and site conditions
Frequently Asked Questions
How do insulated metal siding panels connect to each other?
Adjacent panels engage along matching formed long edges. That engagement is separate from the mechanical fixing to the support.
Do interlocking metal siding panels still need screws?
Yes. The interlock does not replace mechanical fixing to a suitable supporting structure.
Are the screws visible after installation?
In a typical concealed fixing layout the next panel covers the preceding fixing region. Whether any fasteners remain visible depends on the selected detail.
Why is the effective coverage width smaller than the overall width?
The overall width includes the formed connection region. The installed repeat coverage for standard panels is 383 mm rather than the physical width of 430 mm.
Can 16 mm and 20 mm metal siding panels connect directly?
Do not assume compatibility from the identical effective width. Confirm joint details, face levels and any transition with the sales and design team.
Can metal siding panels be joined end to end?
End-to-end extension is a separate detail from the long-edge interlock. Confirm the available H-joint or other appropriate end connection for the selected profile.
Are interlocking panel joints completely waterproof?
The interlock alone should not be relied on as a complete waterproofing or airtightness system. Weather resistance depends on the complete wall assembly, installation and specified flashing and sealing.
Does Tegravo provide installation guidance?
Tegravo usually provides pre-recorded installation guidance videos. On-site guidance and personnel costs, where required, are agreed for the project.
Conclusion
Before making an order, confirm the panel model, its edge joint and specification, the supporting structure and fixing, the layout and accessories, and the details at openings and corners. Send your drawings and selected panel reference to Tegravo to discuss the configuration.