In this guide
To calculate exterior wall cladding area, measure each elevation, subtract doors, windows and other unclad openings, and add the net areas. For metal siding, use the effective installed coverage width and selected panel length to estimate quantities. An area-based count is only the starting point: the actual layout, cuts, accessories and packing must also be reviewed.
Accurate dimensions help contractors, prefab manufacturers and buyers compare lengths, work out their material requirements and prepare a useful enquiry for Tegravo.
Key Takeaways
- Measure gross wall area, subtract only unclad openings and record each elevation separately.
- Use 383 mm effective coverage for standard 16 and 20 mm Tegravo panels, not the 430 mm overall width.
- Review the cutting layout, trims, packing and project requirements before placing an order.
How to measure exterior walls
Work elevation by elevation. On site or from a dimensioned elevation drawing, record horizontal width and vertical height in consistent units, converting millimetres to metres before multiplying. Verify drawing dimensions against site conditions where possible.
Basic wall shapes
- Rectangle: width × height.
- Triangular gable: ½ × base × perpendicular height. Add the rectangular portion below the gable separately.
- Trapezoid: ½ × (parallel side a + parallel side b) × perpendicular distance between them.
Multi-storey and irregular elevations
Divide irregular facades into non-overlapping numbered zones. Record parapets, bays, recesses, returns and projecting surfaces separately if they receive cladding. Measure the actual surface to be clad rather than relying on a single averaged wall height. For complex slopes, send a dimensioned CAD elevation or the confirmed area. Keep repeated elevations and their quantities in the schedule.
How to calculate net cladding area
Gross wall area is the face area before deductions. Opening area is the part that will not receive panels, such as a door, window, garage door or vent. Net cladding area is the area that needs panels.
Net cladding area = Gross wall area − Unclad opening area
Record each opening's width, height and position. Deduct only the actual unclad portion and avoid double-counting overlapping openings. Small penetrations may still require a full panel to be cut around them. Measure opening reveals, internal and external corners, wall abutments, base edges and head trims separately. If a return needs panel cladding, record its surface area as another zone; trims are not included in the face-area calculation.
Worked example: one exterior wall
This fictional 6 m × 3 m elevation has one 1 m × 2.1 m door and a 1.2 m × 1.2 m window. The positions in the sketch are illustrative, not a customer's project.
| Item | Dimensions | Area |
|---|---|---|
| Wall | 6 × 3 m | 18.00 m² |
| Door | 1 × 2.1 m | 2.10 m² |
| Window | 1.2 × 1.2 m | 1.44 m² |
| Total openings | 2.10 + 1.44 | 3.54 m² |
| Net cladding area | 18.00 − 3.54 | 14.46 m² |
Use our wall area calculator to enter your wall and opening dimensions, review the net area and prepare the result for discussion. Panel and pack estimates depend on the supported product data; confirm the final layout with the sales team.
How to convert cladding area into panel quantity
All current Tegravo SKUs have standard 16 mm and 20 mm configurations with a 430 mm overall width and 383 mm installed effective coverage width. The joint and board edge account for the difference. Calculate with the effective width, not the physical board width. A 30 mm configuration has 345 mm effective coverage; ask sales about model, finish, availability and packing before estimating it.
Effective coverage per panel = 0.383 × panel length (m)
For the 3.8 m standard length, one panel covers 1.4554 m². Divide 14.46 by 1.4554 = 9.94, then round up to 10 theoretical panels.
At 8 panels per pack, 10 ÷ 8 = 1.25; a whole-pack estimate is 2 packs, or 16 panels. Neither figure is a cutting schedule or final order.
| Length | Coverage / panel (m²) | Coverage / 8-pack (m²) | 16 mm / pack (kg) | 20 mm / pack (kg) |
|---|---|---|---|---|
| 2.9 m | 1.1107 | 8.89 | 24.88 | 26.66 |
| 3.8 m | 1.4554 | 11.64 | 32.60 | 34.93 |
| 5.8 m | 2.2214 | 17.77 | 49.76 | 53.31 |
These are standard export lengths, not a promise of stock. Pack weights use 2.8 kg/m² for 16 mm and 3.0 kg/m² for 20 mm multiplied by the unrounded effective pack coverage. Cartons and protectors are excluded. Custom structures, lengths and packaging require separate confirmation.
Keep the four quantities separate
- Theoretical panel count: area divided by nominal coverage, rounded up.
- Layout quantity: actual pieces required after joints, cuts and opening positions are reviewed.
- Purchase quantity: confirmed material schedule and any agreed contingency; accessories listed separately.
- Pack quantity: actual packing arrangement for the selected order.
Order quantities are reviewed according to the selected panel specifications and project requirements; colours, styles, thicknesses and lengths may be combined. The 14.46 m² example demonstrates one elevation, not the total quantity for a complete project.
Why panel layout and cutting waste matter
Net area alone does not show how to place panels around windows, whether usable offcuts can be transferred to another wall, or how patterns and end joints align. Installation direction, wall dimensions, profile, openings, corner details and selected lengths all change the cutting plan.
Example contingency calculation
Suppose a buyer adds a hypothetical 5% planning allowance to the net area: 14.46 × 1.05 = 15.183 m². Dividing by 1.4554 m² gives 10.43, rounded up to 11 nominal panels. This is not a universal Tegravo waste rate. Do not add the same waste twice if an actual layout already includes the cuts. The sales and project team confirm the applicable allowance and final quantity.
Measure accessories separately
Record the running lengths of starter, end, opening and corner trims, together with the drawing of each junction. Aluminium accessories suit standard 16 and 20 mm panels; accessories matching the panel finish require customisation. Check profile shapes, lengths and quantities with sales. See panel installation and accessories and what to check before installation.
Choosing the right panel length and packing
A short run may suit 2.9 m; a 3.8 m length may match a different run; a longer 5.8 m panel may reduce end joints when it matches the intended span. Depending on installation direction, longer panels can be harder to handle and may leave significant offcuts. Select lengths against the elevation, transport and cutting plan rather than assuming one length is always most efficient.
Indicative packed dimensions and shipment weight
For initial planning, assume eight panels stacked directly, with a protective packaging layer of up to 5 mm on each outer face. Under that simplified assumption, a pack of 3.8 m × 430 mm panels has indicative outside dimensions of up to 3,810 × 440 × 138 mm for 16 mm panels, or 3,810 × 440 × 170 mm for 20 mm panels. For other standard lengths, replace 3,810 mm with 2,910 or 5,810 mm. Actual stacking geometry, carton design and corner protection can change the outside dimensions.
Shipment gross weight = estimated panel-only weight + actual packaging weight. Packaging thickness alone does not establish its mass. Use the panel-only figures for early freight planning; confirm the packed dimensions and gross weight from the final packing list before booking transport.

Exterior wall cladding measurement checklist
Record the following for each elevation and provide a combined project total before requesting a quotation.
| Field | What to record |
|---|---|
| Building / elevation and repetition | Identify each wall, level or repeated module and quantity. |
| Wall dimensions | Width, height, sloped zones and actual surface area. |
| Openings | Door/window dimensions, location, perimeter and unclad area. |
| Area | Gross, opening and net area by elevation; project total. |
| Panel selection | Preferred model or finish, thickness, length and direction. |
| Accessories | Internal/external corner lengths, opening reveals, starter and end trims, junctions. |
| Drawings | CAD elevations, dimensioned sketches or reference photographs. |
| Shipping | Destination country and port, delivery requirements and packing questions. |
Frequently asked questions
Should windows and doors be deducted?
Deduct areas that do not receive panels. Opening positions, cuts and reveal cladding must still be measured for the layout.
How do I calculate a triangular gable?
Multiply its base by its perpendicular height and divide by two. Add the rectangular wall below, avoiding overlap.
What is the difference between overall and effective width?
430 mm is the overall width of a standard 16/20 mm panel. Its installed effective width is 383 mm, which is used for area estimates.
How many panels do I need per square metre?
It depends on length: approximately 0.90 panels/m² at 2.9 m, 0.69 at 3.8 m and 0.45 at 5.8 m before cuts and contingencies.
How much extra cladding should I order?
There is no fixed waste allowance for every project. Review cuts, openings, pattern alignment and reusable offcuts before agreeing the layout quantity.
Do 16 mm and 20 mm panels cover the same area?
Yes, for the standard configurations at the same length. Both have 383 mm effective width.
How do I convert panels into packs?
Divide the count by eight for the standard pack configuration and round up if planning whole packs. Confirm the actual packing arrangement for the order.
Can Tegravo help with quantities from drawings?
Send the elevations, opening dimensions, preferred panel and installation direction. The team can discuss the panel and accessory schedule with the responsible project team.
Prepare your project information