Skip to content
Shandong Tegravo Building Materials Technology Co., Ltd.
In this guide

Tegravo's insulated metal siding panels are exterior cladding boards built from an exterior metal face, a PU foam core and an inner aluminium-foil and fibre-fabric composite backing. The range is presented in five appearance families. Buyers can use those families to shortlist a look, then confirm the selected panel, its dimensions and the wall details for the project. A panel is one part of an exterior wall; its appearance or specimen data does not establish the performance of the completed wall.

Key Takeaways

  • Three layers: a visible metal face, PU foam core and composite inner backing.
  • Five appearance families help narrow the look; the exact SKU and finish still need checking.
  • Confirm the selected dimensions, effective coverage width and wall details before ordering.

How Is the Panel Built?

The panel has three layers arranged from the exterior face toward the wall: a metal face, a PU foam core and a composite inner backing. Its long edges are formed into a tongue-and-groove joint that connects adjacent panels. The formed edge is part of the panel shape, not an additional layer.

Schematic showing the exterior metal face, PU foam core and inner composite backing as three layers
Figure 1. Three-layer construction schematic: exterior metal face, PU foam core and inner backing. Layer proportions are illustrative.

Visible metal face

The metal face is the visible outer layer. It carries the selected colour, printed finish, coating and surface relief. Compare the chosen model and finish against its product information and physical sample.

PU foam core

The PU foam core forms the middle layer between the exterior metal face and the inner backing. Panel thickness is one of the dimensions to confirm when choosing a model for a project.

Inner backing and formed edge

The wall-side backing is an aluminium-foil and fibre-fabric composite. Along the long edges, the formed tongue-and-groove joint aligns and connects adjacent panels. The edge profile and fixing details are checked with the selected model and wall support.

The assembled wall also depends on its support, fixings, joints, openings, trims and other specified layers. A value measured on a panel or test specimen should not be read as a guarantee for the finished wall. Review the Metal Siding Panels range for the series overview.

What Finishes Are Available?

Beige 7CB-101 brick-look metal siding panel shown at an angle
Figure 2. 7CB-101 brick-look panel, angled view. Appearance reference for one SKU.

The current category pages organise the range by appearance. Each image below is one identified SKU, not every colour or profile available in that category.

FP-WG001 wood-grain panel surface exampleWood Grain FP-WG001
7CB-101 brick-look panel surface exampleBrick Look 7CB-101
LSE-701 stone-look panel surface exampleStone Look LSE-701
SSG-701 solid-colour and textured panel surface exampleSolid Colors & Textured Finishes SSG-701
NFP-701 fluted panel surface exampleFluted NFP-701
Figure 3. Five appearance directions, each represented by one identified SKU. Images are surface references, not a shared colour or dimension standard.

Colour, printed appearance, surface embossing and formed profile are separate decisions. A photograph may flatten relief or shift perceived colour. Confirm the chosen SKU and finish against a physical sample before approving an order. For a closer comparison, read How to Choose Metal Siding Panel Finishes and Profiles.

Who Are These Panels For?

Distributors can compare the appearance families, identify the models and finishes of interest, and send a proposed model mix, quantity, lengths and destination for discussion with the sales team.

Prefab and modular building manufacturers should provide the wall support layout, openings, module joints and planned installation stage. The project team checks where the panels and fixings meet the building, including any transport-related joint details.

Renovation contractors should document the condition of the existing wall, identify the load-bearing support or designed secondary support, and mark openings and exposed edges. The project designer confirms how a new cladding assembly preserves the required wall functions.

What Should You Confirm Before Choosing a Panel?

For a closer comparison, read the 16 mm vs. 20 mm panel thickness guide.

  • The exact panel reference, finish and physical sample; a category name alone is not a model.
  • The available thickness and selected length. Standard thicknesses for current models are 16 mm and 20 mm; regular lengths are 2,900, 3,800 and 5,800 mm. Confirm the chosen combination with sales.
  • The installed effective coverage width. For 16 mm and 20 mm panels, the listed overall width is 430 mm and the installed effective coverage is 383 mm. Use the effective width for area planning.
  • The wall support, proposed fixing positions, direction of installation, openings, corners, exposed ends and matching trims.
  • The project area, destination and any drawings or site photographs available for review.
7CB-101 front view: effective coverage widthRed vertical dimension arrow beside the panel indicates the standard 383 mm effective installed coverage width, not the 430 mm total width. Front view Effectivecoverage width383 mm 7CB-101 angled view and edge detailThe length arrow follows the long side of the panel, with standard lengths 2,900, 3,800 and 5,800 mm. The enlarged end view shows the direction of nominal thickness, 16 or 20 mm. Angled view Length End detailNominal thickness16 / 20 mm Standard lengths2,900 mm3,800 mm5,800 mm
Figure 4. 7CB-101 front, angled and end-detail views with standard dimension directions. Effective installed coverage is 383 mm (total width 430 mm); nominal thickness options are 16 and 20 mm, and regular lengths are 2,900, 3,800 and 5,800 mm. The photos and arrows illustrate the directions, not a measured sample or scaled drawing.

Use the effective coverage width to calculate the installed area. Confirm the chosen nominal thickness and length with sales; the photographed samples illustrate the panel’s appearance and edge, rather than establishing the measured dimensions of an individual piece.

What Information Should You Send for an Enquiry?

Start with the preferred appearance or model, approximate area in square metres, destination country and port, and any target date. If available, add the wall dimensions, openings, support information and drawings or photographs. You can still ask an initial question while some details are open.

Explore the Metal Siding Panels range, read How to Choose Metal Siding Panel Finishes and Profiles for more on appearance selection, or contact our team to discuss a project.