In this guide
Choosing the right thickness starts with the panel specification and the requirements of your wall. Compare installed coverage, panel-only weight, fixing details and accessory options before you decide. Both standard configurations are available across Tegravo's current SKUs; neither is the automatic choice for every building.
Key Takeaways
- 16 mm and 20 mm are standard options across current Tegravo SKUs; both use 430 mm total width and 383 mm installed effective width.
- 16 mm: 2.8 kg/m²; 20 mm: 3.0 kg/m² of effective coverage.
- 20 mm requires longer screws and can provide higher theoretical thermal resistance when the actual foam core is thicker; wall performance must be assessed separately.
- Standard aluminium-alloy accessories suit both; matching decorative accessories and double-steel-faced 20 mm options are customised.
16 mm and 20 mm specification comparison
The following specifications apply to Tegravo's current standard configurations. Confirm the selected model, finish and order details with sales, especially for custom constructions or accessories.
| Specification | 16 mm | 20 mm |
|---|---|---|
| Nominal panel thickness | 16 mm | 20 mm |
| Total width | 430 mm | 430 mm |
| Effective coverage width | 383 mm | 383 mm |
| Panel weight per effective m² | 2.8 kg/m² | 3.0 kg/m² |
| Standard export lengths | 2,900 / 3,800 / 5,800 mm | 2,900 / 3,800 / 5,800 mm |
| Panels per pack | 8 | 8 |
| Approx. panel-only weight per 3.8 m pack | 32.5 kg | 35 kg |
Panel weights are based on effective installed coverage and exclude cartons, corner protectors, accessories and shipping packaging. A custom double-steel-faced construction must be quoted separately; the standard weights above should not be applied to it.
What changes in the panel section
Nominal thickness measures the overall finished section, not the insulation core alone. The standard insulated decorative metal siding construction includes an exterior metal face, PU foam core and an inner aluminium-foil/fibre-fabric composite backing. When comparing samples, check actual overall depth and the edge geometry. See What Are Insulated Metal Siding Panels? for the construction overview.

Coverage and weight for procurement
The 430 mm total width includes the board edge and overlap. The 383 mm effective width is the repeat coverage after installation; use this value when estimating quantities for either standard thickness. For one panel of length L metres, the effective coverage area is 0.383 × L m². Divide the required wall area by that coverage for a preliminary panel count, round up and allow for the actual layout, openings, offcuts and waste. A wall area calculation is not a final cutting schedule.


Worked example for 100 m²
For 100 m² of effective wall coverage, compare the standard panel-only weights before cutting and packing:
| Quantity | 16 mm | 20 mm |
|---|---|---|
| Effective coverage | 100 m² | 100 m² |
| Estimated panel weight | 280 kg | 300 kg |
| Difference relative to 16 mm | — | 20 kg (about 7.1%) |
Both standard thicknesses cover the same area per panel of the same length, so thickness alone does not change the preliminary panel count. For eight 3.8 m panels, each pack covers approximately 11.64 m²; the corresponding panel-only weights are approximately 32.5 kg and 35 kg. At 2.9 m and 5.8 m, eight panels cover approximately 8.89 m² and 17.77 m² respectively. Actual order quantities and freight require the elevation layout, packaging and shipment details. Use the wall area calculator as an initial estimate.
Which models can be ordered in both thicknesses
All current Tegravo SKUs have 16 mm and 20 mm standard options, including wood grain, brick look, stone look, solid colours and textured finishes, and fluted profiles. Start with the required appearance and profile, then specify your thickness. Confirm custom colours, nonstandard lengths, bespoke constructions, matching accessories and delivery requirements separately. Browse the metal siding panel range or compare finishes and profiles.
Connections trims and accessories
The 20 mm panel is thicker and requires longer screws than the 16 mm panel. Confirm the required fastener length, type, fixing arrangement and engagement with the substrate for the specified wall system. Do not select a screw solely by adding the nominal thickness difference. Check edge and opening details, including the joint profile, corner trim, base trim, window and door reveals, flashing and transitions. Do not assume mixed thicknesses can be joined without a transition detail.

Standard aluminium-alloy accessories are suitable for both the 16 mm and 20 mm panels. Accessories that match the panel's decorative colour or pattern need to be customised. Confirm the required trim shapes, dimensions and finish before ordering rather than assuming every accessory item is interchangeable.
For projects requiring greater panel rigidity, a 20 mm double-steel-faced panel can be customised. This differs from the standard foil-backed construction. Ask sales about the proposed face materials, dimensions, weight and validation requirements; do not infer a load rating from the additional steel face. For installation planning, see what to check before installing metal siding panels.
How to choose the right thickness
Consider the building and wall structure before choosing a configuration. The 16 mm standard configuration is lighter; this can be useful when handling and total material weight are priorities. The 20 mm configuration adds depth and weight, so consider it where extra insulation depth is relevant and the frame, fixing and opening details can accommodate it. Neither thickness is universally the right choice for a particular building type.

- Building use: permanent construction, relocatable buildings or exterior refurbishment; required service conditions.
- Wall structure: substrate, framing material and spacing, existing insulation, wall flatness and available space around openings.
- Installation: factory or site assembly, access, lifting, fixing details and sequence of work.
- Thermal and environmental requirements: expected wall-level thermal performance, moisture control, exposure and applicable project requirements.
- Logistics and budget: effective area, lengths, number of packs, measured shipment weight and cost per installed square metre.
Thermal fire and structural performance
With the same insulating material and comparable construction, a thicker actual foam core can provide higher theoretical thermal resistance. This is the advantage of considering the 20 mm configuration when insulation depth matters. However, the nominal overall 16 mm or 20 mm section does not establish the precise core thickness, conductivity, tested panel R-value or complete-wall U-value. Framing, joints, other insulation layers and air leakage all influence the result. Ask for applicable configuration data before making a quantified comparison.
For reaction to fire, fire resistance, wind and other structural requirements, use evidence that corresponds to the actual product and the tested wall assembly. The supports, fasteners, joints, spans and construction details must be considered. A thicker panel or a custom double-steel-faced panel does not by itself establish a fire classification, wind rating or load capacity. No comparative performance figures are claimed here.
What to provide before ordering
Send sales the following information so that Tegravo can confirm the right standard or custom configuration:
- Building type, application and use.
- Chosen SKU, finish, colour and preferred thickness.
- Wall dimensions, estimated effective coverage area, panel lengths and drawings if available.
- Substrate or framing, insulation and fixing conditions, corners and openings.
- Required performance criteria and any applicable project or testing requirements.
- Aluminium accessories, custom matching trims, and whether a double-steel-faced panel is requested.
- Destination country and port, estimated quantity and delivery schedule.

If you are still comparing finishes, request physical samples. Tegravo offers approximately 35 cm sample pieces free of charge; the customer pays delivery costs. Confirm availability of the requested sample and its thickness with sales. Read what to prepare for a quote and the sample and ordering FAQ.
Frequently asked questions
Is 20 mm metal siding better than 16 mm
Not automatically. Both are standard options. The 20 mm panel is deeper and approximately 0.2 kg/m² heavier; the 16 mm panel may be more suitable when weight or available depth matters. Compare the actual wall requirements and the selected configuration.
Do they have the same effective coverage width
Yes. Both standard configurations have a 430 mm total width and a 383 mm installed effective coverage width, so the same standard length covers the same nominal installed area.
Can they use the same accessories and screws
Aluminium-alloy accessories are suitable for both standard thicknesses. Matching decorative accessories need custom production. The 20 mm panel requires longer screws; confirm the fastener specification and detail at each connection with the project team.
Does 20 mm provide better insulation
Greater actual insulating-core thickness can improve theoretical thermal resistance for the same core material. The tested panel and whole-wall performance must be assessed separately; the nominal depth alone cannot establish a quantified result.
Can I request higher rigidity or a sample
A 20 mm double-steel-faced configuration can be customised when greater panel rigidity is needed. Confirm its specification and applicable evidence separately. Physical samples of the requested model, finish and thickness can also be discussed with sales.
Next steps
Compare the finished wall requirements, panel weight and accessory details, then choose the thickness and SKU together. Contact Tegravo with the required area, model references, drawings and destination port so the team can review your configuration and prepare an appropriate quotation. To help select the appearance, see how to compare physical metal siding samples. For joint and fixing details, see how metal siding panels connect.
