In this guide
Before you choose a finish
An existing wall can change the fixing plan, trim layout and amount of panel needed. Record its condition, find the support that will carry the fixings, measure every opening and check the functions the wall must retain.
Inspect the existing wall
Start with each elevation rather than a product photograph. Identify the wall build-up where it is known and mark areas of cracked or loose finish, hollow render, staining, damp patches and earlier repairs. Note changes in wall line, services and places that cannot be inspected from outside.
A photograph can show surface condition but not hidden layers. If the substrate is uncertain, the project team should investigate it before selecting the fixing method or finalising the panel layout.


Find the fixing base behind the finish
Ask where the panel fixings would transfer load. The answer may involve an existing structural member or a designed secondary support system; the actual load path and fixing locations must be confirmed by the project designer or qualified site team. Old render, decorative facing or gypsum board must not be assumed to carry the panels.
Record the wall layers, support positions and any areas where access or drilling is restricted. Fixing type, embedment and spacing depend on the actual substrate, panel system, project design and local requirements. A fixing detail from another building is not a universal installation schedule. Review the renovation project questions.
Measure openings, corners and exposed edges
Mark each door, window, vent and service penetration on an elevation. Provide its width, height and position. Photograph reveals, internal and external corners, the wall base, eaves or head, and transitions to other materials. Identify a practical starting line and the direction in which panels are intended to run.
These records help the supplier discuss board lengths, trims and cutting. The project team still confirms the final layout and weatherproofing details around the openings. Estimate the cladding area from the measured elevations and openings.
Check the functions the wall must retain
New cladding does not by itself establish the performance of the completed wall. The project team should review existing water barriers, flashing and drainage at openings and edges; moisture and drying paths; fire-related elements; and any other required functions under the rules for the building location.
Panel dimensions describe the product, not the waterproofing, wind resistance, fire rating or insulation performance of the full wall. Ask for technical information that applies to the selected panel and thickness when it is needed, and keep the complete-wall assessment with the responsible project team. See the metal siding range.
Turn the site inspection into a supplier brief
The following records allow an initial discussion without pretending that unknown construction has already been verified.
| What you observe | What the project team checks | What to send |
|---|---|---|
| Cracks, damp or loose finish | Extent, cause and repair approach | Whole-wall and close-up photographs marked on an elevation |
| Unknown layers or support | Actual fixing base and access to it | Wall section, drawings, site notes or a clearly marked unknown |
| Windows, corners and services | Layout, trims and weather details | Opening dimensions, edge close-ups and service positions |
| Required wall functions | Applicable project and local requirements | Existing records and the requirements to be reviewed |
Also include the country or region, estimated cladding area, preferred appearance, and any chosen model, thickness or length. You may leave an unknown field open for discussion. Use the installation planning checklist once the wall condition and proposed system are clearer.
Questions buyers often ask
Can panels be fixed directly over old render?
Do not assume the old finish is a suitable fixing base. The project team must identify and assess the member that will carry the fixings.
Does new cladding make the existing wall waterproof?
The finished wall depends on its existing construction and the treatment of openings, edges and penetrations. A panel alone does not establish whole-wall waterproofing.
Which information should be sent first?
Send whole-wall and close-up photographs, wall and opening dimensions, known substrate details, the project location, estimated area and the desired appearance. Mark unknown layers as unknown.
Are 16 mm and 20 mm panels available?
Both are regular thickness options across the current range. The project team must still assess the existing wall and proposed fixing design; discuss other thicknesses and the selected finish with sales.
Discuss the wall before placing an order
Share your wall photographs, support information, opening dimensions, drawings, estimated area, preferred panel appearance and destination country or port. Tegravo can discuss the available panel options and order details while your project team confirms the wall design and installation method.